双向地震下高铁客站抗震性能的振动台试验研究" /> 双向地震下高铁客站抗震性能的振动台试验研究" /> <p style="text-align: center; margin: 0cm 0cm 0pt" class="MsoPlainText" align="center"><span style="mso-ascii-font-family: 'Times New Roman'; mso-hansi-font-family: 'Times New Roman'; mso-bidi-font-family: 'Times New Roman'"><font size="3" face="宋体">双向地震下高铁客站抗震性能的振动台试验研究</font></span><span style="font-family: "Times New Roman"" lang="EN-US"><o:p></o:p></span>
 
 
土木工程学报  2016, Vol. 49 Issue (S2): 69-74    
  结构工程 本期目录 | 过刊浏览 | 高级检索 |

双向地震下高铁客站抗震性能的振动台试验研究

刘汉云1  余志武1,2  国巍1,2  蒋丽忠1,2

1. 中南大学, 湖南长沙 410075
2.
高速铁路建造技术国家工程实验室, 湖南长沙 410075
Shaking table test research of high-speed railway station under bi-directional earthquake excitation

Liu Hanyun 1  Yu Zhiwu 1, 2 Guo Wei 1,2  Jiang Lizhong 1,2

1. Central South University, Changsha 410075, China
2. National Engineering Laboratory for High Speed Railway Construction, Changsha 410075, China
全文: PDF (4213 KB)   HTML (1 KB) 
输出: BibTeX | EndNote (RIS)      
摘要 

房桥合一新型混合结构体系作为高速铁路大型客站典型结构形式,其结构特征复杂,抗震性能并不明确,理论和数值分析之外尚缺少试验论证。以天津西站典型结构为例,进行缩尺比为1/35的振动台模型试验,研究其在多级双向典型地震波激励下的抗震性能,通过试验分析并与有限元计算结果比较,获得了客站典型结构在不同水准双向地震下的动力响应特性和结构损伤情况,指出当前所设计客站结构的抗震性能良好、设计偏于保守、薄弱环节主要集中于上部屋盖结构。

服务
把本文推荐给朋友 双向地震下高铁客站抗震性能的振动台试验研究”的文章,特向您推荐。请打开下面的网址:http://manu36.magtech.com.cn/Jwk_tmgcxb/CN/abstract/abstract272.shtml" name="neirong">
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
刘汉云 余志武 国巍 蒋丽忠
关键词 高速铁路客站 房桥合一 双向地震 振动台试验 抗震性能    
Abstract

Building-Bridge Integrated System BBIS is one of the commonly used structure types in High-Speed Railway station ,and it has a complex structure and unclear seismic performance. Moreover, BBIS structure is still short of experiments to verify. Based on the typical structure of Tianjin West Railway Station example, carries on the scale ratio of 1/35 of the shaking table model test was conducted and research on the multi-stage bidirectional typical seismic behavior under seismic excitation was performed. Through comparing the results of experiment analysis with the finite element calculation, obtain the dynamic response characteristics and damage district of the structure under different level bidirectional earthquake was obtained. Meanwhile, the study points out that the seismic performance of current design station structure is good but conservative, the weak position is mainly concentrated in the upper roof structure.

    
引用本文:   
刘汉云 余志武 国巍 蒋丽忠.

双向地震下高铁客站抗震性能的振动台试验研究[J]. 土木工程学报, 2016, 49(S2): 69-74.
Liu Hanyun Yu Zhiwu Guo Wei Jiang Lizhong. Shaking table test research of high-speed railway station under bi-directional earthquake excitation. 土木工程学报, 2016, 49(S2): 69-74.

链接本文:  
http://manu36.magtech.com.cn/Jwk_tmgcxb/CN/     或     http://manu36.magtech.com.cn/Jwk_tmgcxb/CN/Y2016/V49/IS2/69
主办:中国土木工程学会 地址:北京三里河路9号建设部内

《土木工程学报》杂志社有限公司 版权所有 · 京ICP备05023187号
地址:北京三里河路9号建设部内 邮政编码:100835 电话/传真:010-57811488  E-mail:tumuxuebao@ccej.net